PRODUCTS

AS/NZS Three Core 6.35/11KV XLPE Insulated
Description

Application:
       This cable is used for urban networks. It can be installed aerially, in conduit, on open trays and in underground ducts 
Operating temperature:
       90 & & &,,,,,
 
Voltage rating:
       6.35/11KV
Construction:
       Conductor: Compact round stranded copper or aluminium
       Conductor Shield: Semi-conducting tape and /or semi-conducting cross-linked polyethylene
       Insulation: Cross-linked polyethylene
       Insulation Shield: Semi-conducting cross-linked polyethylene
      Shield: Copper wire shield
       Filler: Polypropylene (Nonhygroscopic material)
       Binding Tape: Polyester and/or non-woven tape (Optional: water blocking tape)
       Armour:Galvanized steel wire
      Sheath: Black polyvinylene (Optional: polyvinyl chloride)

Insulation colour:
     The individual cores shall be identified by the colored strip tapes ,applied under the metallic shielding layer

Followed standard:
      AS/NZS1429.1,AS/NZS1125
Construction data: 
      
Copper conductor,10KA Fault Level  

Nominal Cross sectional area

Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen  wires Nominal over screen wire Unarmoured Steel wire armoured
Approx overall diameter Approx weight of cable Nominal diameter over armour Approx overall diameter Approx weight of cable
mm2 mm mm mm mm2 mm mm mm kg/km mm mm kg/km
16 4.8 3.4 13.0 17.0 10/0.85 16.5 40.5 1500 42.5 47.5 3300
25 6 3.4 14.0 25.5 15/0.85 17.5 43.0 1950 45.5 51.0 4305
35 7.1 3.4 15.0 34.0 20/0.85 18.5 45.0 2400 48.0 53.5 4905
50 8.4 3.4 16.0 49.4 29/0.85 19.5 48.0 2950 50.5 56.5 5650
70 10 3.4 18.0 68.1 40/0.85 21.5 51.5 3900 54.5 61.0 6800
95 11.7 3.4 19.5 68.1 40/0.85 23.0 56.0 4800 58.5 65.0 7950
120 13.2 3.4 21.0 68.1 40/0.85 24.5 59.5 5750 62.0 68.5 9100
150 14.5 3.4 22.5 68.1 40/0.85 26.0 63.0 6650 65.5 72.5 10200
185 16.2 3.4 24.5 68.1 40/0.85 28.0 66.5 7700 69.0 76.0 11500
240 18.4 3.4 26.5 68.1 40/0.85 30.0 72.0 9650 75.5 83.0 14700
300 20.6 3.4 29.0 68.1 40/0.85 32.5 77.5 11600 81.0 89.0 17100
400 23.8 3.4 32.0 68.1 40/0.85 35.5 85.0 14600 88.0 96.5 20700
500 26.8 3.4 35.0 68.1 40/0.85 38.5 92.0 17900 94.5 103.5 24500

      Aluminum conductor,10KA Fault Level 
       
Nominal Cross sectional area Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen  wires Nominal over screen wire Unarmoured Steel wire armoured
Approx overall diameter Approx weight of cable Nominal diameter over armour Approx overall diameter Approx weight of cable
mm2 mm mm mm mm2 mm mm mm kg/km mm mm kg/km
35 7.1 3.4 15.0 23.8 14/0.85 18.5 45.0 1650 48.0 54.0 4150
50 8.4 3.4 16.0 32.3 19/0.85 19.5 48.0 1950 51.0 57.0 4600
70 10.0 3.4 18.0 46.0 27/0.85 21.5 52.0 2450 54.5 61.0 5300
95 11.7 3.4 19.5 61.3 36/0.85 23.0 56.0 2950 58.5 65.0 6100
120 13.2 3.4 21.0 68.1 40/0.85 24.5 59.0 3400 61.5 68.5 6750
150 14.5 3.4 22.5 68.1 40/0.85 26.0 62.5 3750 64.5 72.0 7300
185 16.2 3.4 24.0 68.1 40/0.85 27.5 66.0 4200 68.0 76.0 8000
240 18.4 3.4 26.5 68.1 40/0.85 30.0 71.5 4900 74.5 82.0 9900
300 20.6 3.4 28.5 68.1 40/0.85 32.0 76.5 5700 79.5 88.0 11100
400 23.8 3.4 31.5 68.1 40/0.85 35.0 84.0 6900 87.0 95.5 12900
500 26.5 3.4 35.0 68.1 40/0.85 39.0 92.0 8450 94.5 104.0 15000